RAS Drum Filter Troubleshooting: High Water Level, Frequent Backwash, Solids Carryover and Screen Fouling

Troubleshoot RAS drum-filter overflow, frequent backwash and solids carryover by checking micron size, solids load, water level, nozzles and screen fouling.

A rotary drum filter is a mechanical solids-removal device.
Common symptoms include rising upstream water level, nearly continuous backwash, solids after the filter, low filtered-water flow and screen blinding.

Check Actual Flow

Compare design flow, normal flow, peak flow, bypass flow and pump setting.
A filter can appear dirty when the real problem is hydraulic overload.

Check Screen Micron

A finer screen captures smaller particles but usually creates higher resistance, faster fouling and more backwash.
Do not reduce micron size without checking available screen area and cleaning capacity.

Check Solids Load

RAS solids load changes with feed rate, biomass, fish size, tank cleaning and uneaten feed.
A drum filter sized on flow alone may struggle when solids production rises.

Check Water-Level Control

Many drum filters trigger rotation and backwash from water-level difference.
Verify level sensor, float switch, setpoint, sensor fouling and control logic.

Check Backwash Pressure and Nozzles

Insufficient wash pressure can leave solids on the screen.
Check pump pressure, clogged strainers, valve position, nozzle blockage, spray pattern and manifold pressure.

Check Screen Fouling

Possible foulants include biofilm, grease, mineral scale, fine organic solids and algae.
Mechanical backwash may not remove every deposit.
Cleaning method should match screen material and foulant.

Check Drum Rotation

Verify motor, gearbox, drive, speed and alignment.
Intermittent or slow rotation can reduce cleaning effectiveness.

Check Inlet Distribution

Uneven flow may overload one part of the drum.
Review inlet pipe, baffles, water level and drum submergence.

Check Solids Carryover

Possible causes include screen damage, seal leak, bypass, opening larger than expected or particles smaller than the screen rating.
Inspect the screen and seals before assuming undersizing.

Practical Troubleshooting Table

Symptom
First Checks
High upstream level
flow, screen fouling, micron size
Continuous backwash
solids load, level sensor, screen area
Poor cleaning
pressure, nozzles, fouling type
Solids carryover
screen damage, seals, bypass, micron
Uneven fouling
inlet distribution, nozzles
Excess sludge water
backwash frequency, control setpoint

Technical Basis

RAS studies commonly use drum filters as mechanical solids-removal units before biological treatment. Fine screen selection improves particle capture but also increases hydraulic resistance and cleaning demand.
The practical rule is:
troubleshoot flow, solids load, screen condition, water-level control and backwash system before changing the screen micron.